Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameBEVERLEY APARTMENTS
Address11936 N COMMUNITY HOUSE RD
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 2/20/2023
Final Score @ Grade
26
General CommentsImmediate suspension issued for water quality. Contact Marie Daley at 704-507-6806 when into compliance to lift suspension. Spa must remain closed with signage posted until suspension is lifted by health department. Will verify other permit items at this time including record keeping and doors/gates. “E” Status Updated CPO to Andre Balaguer

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Chlorine 0.2 ppm. .2535(4) Maintain chlorine at least 1.0 ppm. *Immediate suspension item
3 6 Water quality: pool water pH No No No PH 6.8 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. *Immediate suspension item
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing main drain checks, weekly cyanuric acid and alkalinity. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *30 Day Intent to Suspend (ITS) item. Will verify on return visit
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer with leaves and debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned and corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Resident door onto pool deck not self- closing due to artificial grass. One gate not self-closing, self-latching. 2537(b) All gates and doors shall be self-closing, self-latching..2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator corrected door to self-close, self-latch. Condition of permit: 2) Doors From Apartments Must Remain Accessible And Self-closing, Self-latching. Approved Barrier. *ITS item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak under spa pump. .2533(d) Pump room floor shall be kept dry and free of standing water.