2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Chlorine 0.2 ppm. .2535(4) Maintain chlorine at least 1.0 ppm.
*Immediate suspension item |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
PH 6.8 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8.
*Immediate suspension item |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records missing main drain checks, weekly cyanuric acid and alkalinity. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*30 Day Intent to Suspend (ITS) item. Will verify on return visit |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer with leaves and debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator cleaned and corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Resident door onto pool deck not self- closing due to artificial grass. One gate not self-closing, self-latching. 2537(b) All gates and doors shall be self-closing, self-latching..2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Operator corrected door to self-close, self-latch.
Condition of permit:
2) Doors From Apartments Must Remain Accessible And Self-closing, Self-latching. Approved Barrier.
*ITS item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Leak under spa pump. .2533(d) Pump room floor shall be kept dry and free of standing water. |