20
|
0
|
Proper cooling time & temperatures |
Yes |
No
|
No |
3-501.14(B) Quickly cool TCS foods that are prepared from room temperature ingredients. Food must be to 41F within 4 hours. -P. Observed collard greens and pinto beans prepared from cans have no change in temperature after cooling for close to 60 mins. CDI- see item #33. Items not discarded due to being within time parameters.
For more information, please visit: www.meckncgov/foodsafety or view our training videos at the following weblinks: What are TCS Foods https://www.youtube.com/watch?v=q0iLZb7v0UM and Cooling Food Safely https://www.youtube.com/watch?v=P6x8b1ZVOxU . |
|
33
|
0.50
|
Proper cooling methods used; adequate equipment for temperature control |
Yes |
No
|
No |
3-501.15 Quickly cool foods. Use methods such as open/vented shallow pans, large ice baths and active stirring. Cold air must flow around product to remove the heat. -Pf. Observed large deep densely packed metal pans holding Pinto beans and collard greens cooling in reach in unit with ambient temp of 40F. CDI- EHS discussed with PIC methods including use of shallow pans, spacing, ice bags, and using reach-in freezer for initial rapid cooling. PIC used iced bags before moving items to shallow pans to be placed in reach-in freezer for rapid cooling.
For more information, please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Cooling Food Safely https://youtu.be/P6x8b1ZVOxU . |
|
38
|
0
|
Insects & rodents not present; no unauthorized animals |
No |
No
|
No |
6-501.112 Remove dead or trapped birds, insects, rodents, and other pests. Observed insect trap needing to be cleared. |
|
49
|
0.50
|
Non-food contact surfaces clean |
No |
Yes
|
No |
4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris.4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. Observed gaskets on cold holding units needing to be cleaned. Bottom shelf of prep table needing to be cleaned. *REPEAT* |
|
55
|
0.50
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
6-101.11/6-201.11 Floors, walls and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable. Floors shall be non-absorbent in areas subject to moisture.
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair.
Observed large patch of floor tiles missing under prep sink in kitchen. Repair floor tiles so they are smooth and easily cleanable. *REPEAT* |
|
56
|
0
|
Meets ventilation & lighting requirements; designated areas used |
Yes |
No
|
No |
6-305.11/6-501.110 Designate and use an area for the orderly storage of employees' clothing and possessions. Observed employees personal phone being held on prep table. CDI- PIC had employee remove phone to designated area. |