Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePIEDMONT, THE
Address1301 IVY MEADOW DR
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/8/2021
Final Score @ Grade
40
General CommentsInspection conducted with Christopher Bergensten. Due to COVID-19 precautions, inspection was not signed by the operator. Verified that F-300 flow meter installed 6" from downstream elbow, accurate to +/- 10%. VFD set at 53 Hz, XFK-20 pump operating at 178gpm after fresh backwash, this is within the permit condition of 145-196 gpm. PDSC form on file not accurate. Fill out and submit updated PDSC form with corrected drain sump information, verify if main drain piping is 3" or 4". CPO on file no longer at this pool. Updated file with new CPO information. Immediate suspension issued 15) 22)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Non-slip tread missing from one of the ladders. .2521 Install ladders per manufacturer instructions.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Skimmer equalizer lines plastered over, but not plugged in the skimmer. Ensure skimmers are abandoned per state guidelines. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Intent to suspend item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope 47 feet long. .2530(a) Provide USCG approved ring buoy with 45 foot long throw rope at least 1/4" in diameter. - Intent to suspend item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door to clubhouse does not latch, not alarmed. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. - Intent to suspend item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some deck chairs too close to pool edge or ladder. .2522(e) Provide at least 5 ft of clear walking space around diving board, handrail, slide, or other permanent structure on a swimming pool deck. .2522(a) Provide 6 ft of clear walking space around the pool at all times.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Underwater light not secured to the pool wall. .2537(9) Underwater light niches shall be maintained or covered so not to present a hazard. - Intent to suspend item.
22 6 Premises: emergency telephone provided No No No Emergency phone not functioning. .2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system. - Immediate suspension item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Eyeball fitting installed on vacuum line closest to the pump room. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. Corrected by operator.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not functioning in the pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Fan not functioning in the chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Lighting not functioning in the chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Newly installed piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in the restroom > 110F. .2526(i) Water in restrooms shall not exceed 110 F.