| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Pre-permit item. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Fitting missing for autofill. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Pre-permit item.
Two of the skimmers missing equalizer line plugs. Plug equalizer lines per state guidelines. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. - Pre-permit item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Main gate not self-closing and self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Pre-permit item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Post for canopy too close to ladder. .2522(e) Provide at least 5 ft of clear walking space around diving board, handrail, slide, or other permanent structure on a swimming pool deck. - Pre-permit item.
Post for canopy too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Pre-permit item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Self-closing vacuum cap broken. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Pre-permit item.
Flow meter not functioning. .2518(g) Keep flow meter operational. - Pre-permit item.
Filtration pump off, part of the facility lost power. .2518(b) The system shall be operated 24 hours a day. - Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Some chemicals stored in pump room. Chemical storage room full of stockpiled chemicals and some non-chemical items. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. - Pre-permit item. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Return line not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels. - Pre-permit item. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
One stall in women's restroom without toilet paper. .2526(l) Provide toilet paper and dispensers in restrooms. - Pre-permit item. |
|