Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameVILLAGE AT COMMONWEALTH II SPA
Address1353 IRIS DR
 
City/State/ZIP
CHARLOTTE NC 28205
Premise Type55 - Year-Round Spa
CountyMecklenburg
Inspection Date 1/13/2021
Final Score @ Grade
18
General CommentsNo signature was collected due to COVID-19 precautions. “issuance of a permit by this department does not negate closure required by Executive Order No. 120, 138, 141, 147, or subsequent Orders in effect unless such Orders are rescinded or superseded by another applicable Order.” It is recommeded that an additional gate by placed at the fence at the top of the stairs near the building entrace doors. This gate would not be part of the overall pool barrier, but would help discourage children from accidental entry and from people bringing pets through the area. The outer barrier is the official pool barrer and all gates and doors must be compliant in addition to the permit restrictions being observed for widows and doors on the apartments and buildings.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
14 4 Pool maintenance: spa timer working properly No No No Observed spa timer to run longer than 15 minutes. Timer shall run no longer than 15 minutes.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed gate at the bottom of the stairs near the street to self close, but not to fully self latch. All gates and doors must fully self-close and self-latch. This gate is considered part of the pool barrier due to the way the pool area was built initially. All Permit restrictions on doors and windows must be maintained as well.
18 4 Premises: lifeguards present or warning signs posted No No No Observed spa sign to have the typographical error "...raise or lower the blood pressure" rather than the required "raise or lower blood pressure". Sign could be corrected by covering "the" in the phrase.
22 6 Premises: emergency telephone provided No No No Observed kings III box non-functional. Box must function and have a working call-back number that is posted with local 911 service along with the proper address. Proper address and call-back number must correct and on file with local 911. PERMIT SUSPENDED POOL CLOSED TO SWIMMING. Contact C. Elmore when correction is made. Box must function. Call back number and address must be both properly posted on the sign and on file with local 911. Call back number must ring back the call box for voice communication with the box. Pool cannot open back up until after the Health Department verifies corrections.