Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAVALON SOUTH END
Address2250 HAWKINS ST
 
City/State/ZIP
CHARLOTTE NC 28203
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/30/2024
Final Score @ Grade
26
General CommentsIntent to Suspend issued for: .2535 - provide DPD-2 reagent .2537 - repair deck - hole at autofill and missing caulk between coping and deck .2530 - provide warning no lifeguard on duty in 4" lettering at far end of pool .2528 - repair gate to self-close, self-latch .2518 - repair flow meter so operable Paul and Lance present during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No DPD-2 reagent expired. Replace reagent. Intent to Suspend issued.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Floor jet returns missing fittings. Openings not greater than 1/2". Keep fittings in place and in good repair. Light niche near ladder missing fitting. Replace fitting.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate closest to parking area locked shut with bike lock. Was able to verify gate does not self-latch. Repair to self-close, self-latch. Ok to remain shut with bike lock once repaired. Intent to Suspend issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Hole next to autofill and missing caulk around corner of coping near autofill. Patch/seal to provide impervious surface. Intent to Suspend issued. Polymeric sand beginning to degrade within 6 ft. of pool edge. Will require repair prior to 2025 operating permit to provide impervious surface within 6 ft. of pool edge. Deck offset near restroom worsening. Continue to monitor. Provides a trip hazard. Does not meet slope requirement of 1% - 2% but outside of required deck space. Pool furniture within 6 ft. of pool near restrooms. Maintain 6 ft. clearance around the pool.
18 4 Premises: lifeguards present or warning signs posted No No No Warning signage located by far gate entry not sized and with not accurate wording. Provide "Warning No Lifeguard on Duty" in at least 4" lettering visible upon entry to the pool. Intent to Suspend issued.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operable. Keep operable. Intent to Suspend issued.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemical storage room left unlocked with no one present from property. Ensure chemical storage room is kept locked when not in use.