Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAVALON SOUTH END
Address2250 HAWKINS ST
 
City/State/ZIP
CHARLOTTE NC 28203
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/13/2021
Final Score @ Grade
26
General CommentsGermaine Murray present during the inspection. No signature due to covid restrictions. Intent to Suspend issued for light fixture. 15 - Beckets on ring buoy not attached. Replace ring buoy within 30 days.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Water level high due to rainstorm previous evening. Lower water level to ensure skimmers working properly. Some debris in skimmers. Keep baskets free of debris.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Part of 4 in 4 ft depth marker by bench chipped. Filled in with permanent marker. Continue to monitor and may require repair in future if worsens.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Light missing fixture fitting at far end of pool. Replace fitting on light. Intent to Suspend issued. One return fitting not tight to wall. Screw back into fixture to ensure in place.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some pool furniture 5 ft to pool edge. Maintain 6 ft. clearance around pool in all areas. Polymeric sand washed out around autofill. Opening <1/2".
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Small leak at chlorinator. Repair so no leak. Flow meter on chlorinator installed on return line to system rather than line into chlorinator. Install per NSF requirements.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operable. Repair so operable. No spare pump basket for Whisperflo pump. Provide spare pump basket for Whisperflo pump. WFE-8 pump.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Floor wet under chlorinator. Small leak. Floor in pump room shall be kept dry.