5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed gaps in the record book. Keep proper records. No permit action taken. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
.2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool.
Observed missing depth marker that makes the distance between markers on the deck 38 feet. This must be corrected.
.2523(d) No Diving markers shall be provided in all areas of the pool less than five feet deep. Observed missing no dive markers that makes the distance between makers greater than 25 feet. (Approx. 32 feet.) this must be corrected. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2522(g) Decks and walkways shall be slip-resistant. Observed blank tiles in the places where the depth and no diving tiles are missing. They are slick topped and do not meet the slip resistant requirements for pool tiles. This must be corrected. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Observed chlorine pucks in the skimmer baskets. This presents a hazard. Chlorine pucks and other chlorine chemicals cannot be placed into the pool directly for normal operation.
The chlorine must go into the pool by means of the chlorination system when the pool is open to swimming. Pool is closed by order of the Health Department.
Call C. Elmore (704-507-6814) when the chlorination system is fixed. Pool cannot reopen prior to verification visit by the Health Department. I.S. Issued. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep flow meter operational. Observed flow meter stuck. Fix the flow meter. |