Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLANIER VILLAGE
Address8503 MANSELL COURT
 
City/State/ZIP
CHARLOTE NC 28215
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/14/2025
Final Score @ Grade
40
General CommentsPermit restriction umbrella must remain in place at all times pool is open. Padding must remain intact around base of umbrella.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Inside pool has crack running down side wall at 5ft area Zero beach entry has crack and needs to be filled. Crack greater than 1/2 inch filled with pool putty during inspection .2537(14) Keep pool surface and pool floor free of debris in good repair
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Clean skimmer baskets that was filled with debris .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Inlet for auto fill needs eye ball .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No The throw rope was in disrepair and new ring buoy was installed during inspection .2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Magnet creating foot hold with in 45 inches. Plexiglass placed at bottom of fence to get rid of foothold .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010).
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed chair lift hole not covered. Needs cover or filled in when not in use. Covered during inspection .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Chairs within 8ft of pool deck. Moved during inspection .2522(a) Provide 8 ft of clear walking space around the pool at all times (>1600 sq. ft).
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. New sign installed during inspection
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency phone shall remain operable. Phone did not ring and new phone was installed during inspection
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Observed exhaust fan not working .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Need backflow preventer on spigot prior to chemical room .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer.