5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No cyanuric acid checks, checking calcium hardness instead of cyanuric acid. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Pre-permit item.
Test kit expired. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. - Pre-permit item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
All nine weirs missing. .2518(k) Provide functional weirs. - Pre-permit item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
All ladders missing escutcheon plates. .2521 Install ladders per manufacturer instructions.
All handrails missing escutcheon plates. .2521 Install handrails per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Facility with one set of lifesaving equipment. Provide a second US Coast Guard approved ring buoy with attached 46 foot 6 inch throw rope and second body hook on 12 foot non-collapsible pole. .2530(b) Two units of lifesaving equipment (or two lifeguards) must be provided for pools that exceed 3,000 sq. ft. surface area. Must be easily visible and accessible. - Pre-permit item. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone not visible from all areas of the pool. Post additional signage noting location of the emergency phone. .2530(f) Emergency phone shall be visible from all areas inside pool enclosure. - Pre-permit item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not working. .2518(g) Keep flow meter operational. - Pre-permit item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Some buckets of chemicals stored next to pool equipment. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
Some buckets of chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Dry bag of soda ash on the chemical storage room floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. |