Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameWATERMARK LAKE NORMAN
Address19329 WATERMARK DR
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/9/2024
Final Score @ Grade
28
General CommentsOn-site visit for seasonal permitting inspection. EHS unable to issue permit. Facility completed renovation/construction in pump room. Per PIC, electrical permit pulled and passed. PIC to provide copy to EHS prior to scheduling re-inspection. NOTE: PERMIT CAN BE ISSUED FOR 2024 SEASON; HOWEVER, PRIOR TO 2025 SEASON POOL DECK MUST BE SLOPED TO DRAIN/REPAIRED. IN-FIELD PLAN REVIEW REQUIRED. CONTACT TIME DUCTHER (704-507-6808) OR KATIE RUDISILL (704-309-5494). FAILED INSPECTION. EHS placing facility in "Q" status. Upon making corrections to violations noted during inspection, contact the main office at (980)-314-1620 and request pool re-inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed no section/column in log book for recording total alkalinity or cyanuric acid.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed ring buoy with rope length of 45ft (based on pool square footage rope must be 46.6ft).
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed doors with direct access to pool deck inaccessible- residents not notified/not at residence during inspection. Fencing around perimeter of pool not to code.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed cabanas next to pool with less than 6ft clear walking space. .2522(f) Deck shall be sloped to drain. Observed no drains on pool deck. PERMIT CAN BE ISSUED FOR 2024 SEASON; HOWEVER PRIOR TO 2025 SEASON POOL DECK MUST BE SLOPED TO DRAIN/REPAIRED. IN-FIELD PLAN REVIEW REQUIRED. CONTACT TIM DUCTHER (704-507-6808) OR KATIE RUDISILL (704-309-5494).
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency phone shall remain operable. Observed emergency phone unable to be called back. EHS able to dial out to 911 (phone # and address on file with 911 is correct).
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed flow meter inoperable. PIC able to make flow meter operate but meter gets stuck easily.