Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameATHERTON, THE
Address2100 SOUTH BLVD
 
City/State/ZIP
CHARLOTTE NC 28203
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/6/2022
Final Score @ Grade
14
General Comments15 - Ring buoy grab rope degrading. Replace within 30 days. Will verify during return inspection. 16 - Windows not verified due to access. Ensure window limiters in place at 4" or less. Intent to Suspend issued for decking repairs - .2522/.2537

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No main drain checks for August. Old log was used for the month of August. New logs have section for main drain checks.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some algae around ladder end caps. Monitor algae and eliminate.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Leak near deck drain located nearest to club room. Pavers had been removed and not replaced as sloped to drain. Deck drain and autofill offsets. Once repair has been made to leak at drain, ensure decking is installed sloped to drained and sealed with polymeric sand. Deck drain and autofill shall be flush to the deck as to not present a trip hazard. Given 30 days for completion. Intent to Suspend issued. If needing additional time, provide scope of work for completion. Deck drains beginning to rust again. Continue to monitor and repair if worsens or becomes a hazard. Polymeric sand on deck missing or damaged in some locations around pool. Decking shall remain impervious within 6 ft. of the deck edge. Requires repair prior to 2023 operating permit.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor wet due to leak around backwash pit. Repair leak to maintain floor dry. Lights burnt out in pump room. Replace lighting where needed.