3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Pool water pH greater than 8.0. Immediate suspension item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
EHS could not verify records during visit. Ensure records are complete and ready to review upon return visit. Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing or damaged skimmer basket.
Skimmer basket broken near pump room. Replace.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
All skimmers full of leaves and debris. Clean out.
EHS could not confirm weirs due to skimmer debris and high water level. Ensure all weirds are present and functional.
Intent to suspend items. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope tangled and inaccessible. Immediate suspension item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Pool gate shall be at least 48" in height measured from outside of barrier.
Some furniture pressed up against patio fencing from outside creating a foothold. Remove footholds and remind residents to keep furniture away from pool facing patio fencing. Intent to suspend item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Filter pump flow meter functional but reading 45 GPM. Per permit condition, flow must be between 84gpm and 89gpm to meet turn over and pipe size limitation. No suction hazard. Intent to suspend item. |