| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 8.2 at time of inspection.
.2535(1) Maintain pH at 7.2 to 7.8
*Immediate suspension item. Operator added acid and corrected to 7.4. Pool voluntarily closed while chemicals are balanced. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Some daily records missing on day of inspection, multiple months of same readings daily. Reading should be recorded, then maintenance of adjusting water quality to reflect work done on pool.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records.
*Permit item |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Leaves covering main drains at time of inspection.
.2537(14) Keep pool surface and pool floor free of debris. Operator cleaned and corrected. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Some debris in skimmers at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator emptied and cleaned. Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Balcony chairs, furniture, coolers and items on multiple balconies creating horizontal less than 45" in height. .2528(b) Horizontals shall not be located less than 45" in height.
Gate metal piece has been moved, creating gaps greater than 1/2" within 18" of latching mechanism.
.2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism.
*Permit items |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some items and chairs within 6' of pool.
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved and corrected. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Trash can blocking emergency phone at time of inspection.
.2530(f) Emergency phone shall be accessible to all pool users. Operator moved trash can and made accessible. Corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Vacuum cap in pool with screw protruding out, causing hazard. Keep in good repair. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010.
Operator removed screw, replaced cap and corrected. |
|