11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Both ladders missing end caps. .2521 Install handrails per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Throw rope heavily knotted. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope at least 1/4 inch in diameter. - Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Gate by shower not self-closing. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fan not working in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. |