NameMALLARD GLEN APARTMENTS
Address2401 ROSY BILLED DR
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/22/2021
Final Score @ Grade
16
General CommentsInspection conducted with Seth Pardon. Due to COVID-19 precautions, inspection was not signed by the operator. Note: No label on pump. Observed Sta-Rite Pump with 3 HP motor. New gates and surrounding fencing installed. Ensure gates operate on a battery backup or are designed to stay latched in the event of a power outage. Some coping tiles cracking. Recommend patching or replacing. Permit denied for the following items 15) 16) Inspection did not pass. A $100 reinspection fee will need to be paid prior to scheduling a reinspection. This can be done by calling our main office (980-314-1620) and paying with a credit card.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One eyeball fitting missing. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope 29 feet long, pool 33 feet wide. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope. - Pre-permit item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence with gaps > 4" under the fence in places. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). New gates installed. Gaps > 1/2" within 18" of the push bar. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. - Pre-permit item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak at pump. .2533(d) Pump room floor shall be kept dry and free of standing water.