| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No total alkality or cyanuric acid readings for March. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections,and pool water maintenance activities. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
No flow in the skimmers. .2518(k) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow rated under NSF 50. - Intent to suspend item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed ladder missing one endcap. .2521 Install ladders per manufacturer instructions. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pre-2010 fence < 48" high in places. Fence with footholds < 30". .2528 Pool fence shall be at least 48" in height measured from outside of barrier and with footholds no less than 30 inches for pre-2010 fencing. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone not functioning. .2530(f) Emergency phone shall remain operable. - Corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Pump basket not installed correctly and damaged, allowing leaves and debris into the impeller. Both spare baskets damaged as well. .2518(e) Provide a spare basket for pump. - Intent to suspend item.
Pump does not seem to be working properly. No flow in the skimmers. .2518(b) The pool circulation system shall be sufficient to clarify and disinfect the entire volume of the pool four times in 24 hours. - Intent to suspend item.
Flow meter reads 35 GPM, but is air locked. .2518(g) Keep flow meter operational. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fan not functioning in the chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. |
|