Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameADAMS PLACE CONDOMINIUMS
Address10105 REVOLUTION CT
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/29/2023
Final Score @ Grade
26
General CommentsInspection conducted with Michael Wells. NOTE* Skimmers turned off in the pump room. Even after turning the valve back on still no flow in the skimmers. Large amount of bubbles coming from the floor returns. Pump strainer basket lid opaque, not able to determine when it needs cleaned. Recommend cleaning or replacing. Shower nozzle creates a sharp stream. Recommend replacing with a conventional shower head. Exposed wiring by pump room door. Recommend replacing broken lid for electrical box. Intent to suspend issued. 5) 8) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No total alkality or cyanuric acid readings for March. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections,and pool water maintenance activities. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No No flow in the skimmers. .2518(k) The flow-through rate through any one skimmer shall be between 20 GPM and the maximum flow rated under NSF 50. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed ladder missing one endcap. .2521 Install ladders per manufacturer instructions.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence < 48" high in places. Fence with footholds < 30". .2528 Pool fence shall be at least 48" in height measured from outside of barrier and with footholds no less than 30 inches for pre-2010 fencing.
22 6 Premises: emergency telephone provided No No No Emergency phone not functioning. .2530(f) Emergency phone shall remain operable. - Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Pump basket not installed correctly and damaged, allowing leaves and debris into the impeller. Both spare baskets damaged as well. .2518(e) Provide a spare basket for pump. - Intent to suspend item. Pump does not seem to be working properly. No flow in the skimmers. .2518(b) The pool circulation system shall be sufficient to clarify and disinfect the entire volume of the pool four times in 24 hours. - Intent to suspend item. Flow meter reads 35 GPM, but is air locked. .2518(g) Keep flow meter operational. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not functioning in the chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.