NameADAMS PLACE CONDOMINIUMS
Address10105 REVOLUTION CT
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/22/2021
Final Score @ Grade
20
General CommentsInspection conducted with Seth Pardon. Due to COVID-19 precautions, inspection was not signed by the operator. No label observed on pump. Observed Pentair Challenger pump with 1 1/2HP motor. Newly installed electronic gate latch. Ensure that latch operates on a battery backup or is designed to remain latched if there is a power outage. Offsets between coping and deck. Maintain deck so there are no gaps or offsets > 1/2". Caulking deteriorating along coping. Recommend re-caulking. Immediate suspension issued 22) Inspection did not pass. A $100 reinspection fee will need to be paid prior to scheduling a reinspection. This can be done by calling our main office (980-314-1620) and paying with a credit card.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No New electronic gate latch installed extends out 4", < 45" high creating a foothold. .2528(b) Gate horizontals and footholds shall not be located less than 45" in height. - Intent to suspend item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck chair too close to pool edge. .2522(a) Provide 6 ft of clear walking space around the pool at all times. - Corrected.
22 6 Premises: emergency telephone provided No No No Unable to get emergency phone to pick up when called. Unable to reach 911. .2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system. - Immediate suspension item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not functioning in the chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.