33
|
0.50
|
Proper cooling methods used; adequate equipment for temperature control |
Yes |
No
|
No |
3-501.15 Quickly cool foods. Use methods such as open/vented shallow pans, large ice baths and active stirring. Cold air must flow around product to remove the heat. -Pf. Observed diced tomatoes cooling at a rate of 0.02F/min and shrimp cooling at a rate of 0F/min. Diced tomatoes were cooling in a container tightly covered with a lid. Shrimp was cooling wrapped in portion bags and stacked. CDI: PIC placed items in ice bath to cool.
For more information, please visit: https://health.mecknc.gov/envhealth/food-and-facilities-sanitation or view our training videos at the following weblinks: What are TCS Foods https://youtu.be/bRvqAETDjQU and Cooling Food Safely https://youtu.be/P6x8b1ZVOxU |
|
43
|
0
|
In-use utensils: properly stored |
No |
No
|
No |
3-304.12 (A) In-use utensils in TCS food, must be stored with handles above the food and top of the food container. Observed tongs with handles touching food items such as spring mix, dumplings and meatballs.
3-304.12 (F) Containers of water used for storing in-use utensils must be maintained at a temperature of at least 135 F and cleaned at least every 24 hours or when container has accumulated soil or residue. Observed utensils being stored in water at 73F. |
|
48
|
0.50
|
Warewashing facilities: installed, maintained & used; test strips |
No |
No
|
No |
4-302.14 Provide a test kit that accurately measures sanitizer concentrations. -Pf. Observed facility without quat test strips. VR required within 10 days. |
|
49
|
0
|
Non-food contact surfaces clean |
No |
No
|
No |
4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris.4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. Observed prep units, reach in cooler and sides of grill heavily soiled with food debris. Increase cleaning frequency. |
|
55
|
1
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
REPEAT