3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. - Observed the pool pH to be at 8.0 at the start of the inspection.
CDI - pH corrected to 7.6 by the end of the inspection. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521(b) Ladders shall have slip-resistant tread. - Observed one ladder to be missing the slip resistant tread on the middle step. Replacement step was noted in the pump room but has not been installed yet. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep the flow meter operational. - Observed the flow meter to not be working at the time of the inspection. 30 day ITS to be issued. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room; .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. - Observed the ceiling ventilation fans to not be working in both the pump room and the chemical room at the time of the inspection.
.2533(d) Pump room floor shall be kept dry and free of standing water. - Observed one valve to the pool filter to be leaking causing the pump room floor to be wet at the time of the inspection. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
.2518(d) Piping and valves shall be labeled with color codes with a legend or labels. - Observed the pipes in the pump room to be mislabeled with multiple pipes being labeled for the main drain. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
.2512 (b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap or vacuum breaker (ASSE 1020 or 1013). - Observed both of the hose bibs on the deck to not be provided with vacuum breakers. |