2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Water smells like bleach, bleached out test kit. G.S. 130A-2(3) Chlorine bleached out test kit. Imminent Hazard to public. Lower to measurable level. - Immediate suspension item. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 6.8. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Chlorine consistently 3ppm for last few months, Cyanuric acid consistently 30ppm last few months. Ensure chemicals are tested with a test kit. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
Cyanuric acid tested at well over 100 ppm today. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. - Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Most skimmer baskets with debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item.
One weir installed backwards. .2518(k) Provide functional weirs. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
One ladder missing bottom step and endcaps. One ladder missing non-slip tread. .2521 Install ladders per manufacturer instructions.
One ladder extends > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Throw rope 53.5 ft long. .2530(a) Provide 50 foot throw rope at least 1/4” in diameter for US Coast Guard approved ring buoy. - Immediate suspension item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pre-2010 fence with gaps > 4” through fence in places. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Phone number posted does not match what 911 has. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Immediate suspension item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Leak at filter multiport. .2533(d) Pump room floor shall be kept dry and free of standing water. |