| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 6.9. .2535(1) Maintain pH at 7.2 to 7.8. Corrected to 7.2. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No recent total alkalinity or cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer baskets cracked or damaged. .2518(k) Replace missing or damaged skimmer baskets. - Intent to suspend item. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Both ladders missing endcaps. .2521 Install ladders per manufacturer instructions.
One ladder extends > 6" into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
One inlet fitting missing. .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. |
|
13
|
4
|
Pool maintenance: contrasting band on steps and benches |
No |
No
|
No |
Contrasting tile on bench 2.5" from leading edge. .2516(b) Underwater benches shall be marked by a two inch contrasting color band on the leading edge. 2"x 2" contrasting tile is acceptable if installed within 1" of the edge of the stair tread and adjacent tiles.
Contrasting tile on stairs 3" from leading edge of step, does not extend all the way to pool walls. .2521(b) Leading edge of stair treads shall be marked with a contrasting color band at least two inches wide. 2"x 2" contrasting tile is acceptable if installed within 1" of the edge of the stair tread and adjacent tiles. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Gaps greater than 4" under the fence. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
Fence with footholds. .2528(b) Horizontals shall not be located less than 45" in height. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Phone number posted does not match what 911 has. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Some chemicals stored in the pump room. Store chemicals in the chemical storage room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Backflow preventers not installed on hose bibbs on pool deck .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer. |