5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No place on log sheet for main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Leak at fill line. .2533(d) Pump room floor shall be kept dry and free of standing water.
Some items stored beside pool filter. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Shower sign not posted. .2526(a) Post a shower sign visible upon entrance to the pool. |