5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No log book maintained. Maintain daily record keeping for chlorine, pH and main drain checks. Maintain weekly record keeping for cyanuric acid and total alkalinity. Intent to Suspend issued.
Cyanuric acid above 100 ppm. Maintain at 100 ppm or below. Intent to Suspend issued.
Reagents in liquid test kit expired. Replace expired reagents. Intent to Suspend issued.
No documentation for CPO. CPO indicated he did not have onsite. Provide documentaiton on CPO. Intent to Suspend issued. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One skimmer weir missing. Replace. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Small leak at gasket at chlorinator. Continue to monitor and repair if worsens. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Floor wet under chlorinator due to small leak at gasket. Repair leak and keep floor dry. |