5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Observed daily/ weekly records being kept sporadically. Maintain records as required.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed 1 of four weirs missing. Replace. Observed excessive leaved and debris in skimmers. Keep skimmers free of debris.
.2518(k) Replace missing weirs.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Observed both ladders missing end caps. Replace missing end caps. Observed ladders extending greater than 6” from pool wall. Repair.
.2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
.2521 Install ladders per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Observed grab rope on ring buoy and throw rope brittle. Replace ring buoy and throw rope. Immediate suspension item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed 2 of 3 gates not self-closing/ self-latching and door from clubhouse to pool deck not self latching or equipped with and audible alarm. Repair. Also observed vertical members of fence with gaps grater than 4 inches. Repair.
.2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010).
.2537(b) All gates and doors shall be self-closing, self-latching.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Observed leak at chlorinator in pump room. Repair leak.
.2533(d) Pump room floor shall be kept dry and free of standing water. |