Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHEATHER RIDGE
Address8800 MEADOW VISTA RD
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/23/2023
Final Score @ Grade
22
General CommentsIssued intent to suspend for records and non latching gate. Correct items within 30 days. Call James Bjorneboe@704-507-6820 once items have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed no records for total alkalinity or cyanuric acid in 2023. Maintain records for total alkalinity and cyanuric acid on a weekly basis. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed debris in skimmers. keep skimmers free of debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed ladders missing end caps. Replace missing end caps.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed one gate not self-latching. Repair gate so that is self latches. .2537(b) All gates and doors shall be self-closing, self-latching.
22 6 Premises: emergency telephone provided No No No No phone number posted at emergency phone. Corrected on site. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Observed clutter and debris in pump room. Keep pump room clean.