Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLINKS AT REA FARMS, THE - NORTH
Address7420 N REA PARK LN
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/25/2026
Final Score @ Grade
12
General CommentsPool not heated. No night swimming. New automatic feeder installed. Verified shuts off with pump. One door onto pool deck from lobby locked with no key available. Unable to check. If door is ever unlocked or in use, must self close, self latch or have audible alarm. Garage window from serving area onto pool deck can NOT open more than 4”. Inspection with Ezequiel Espinal Note: Emergency operator noted hard to hear receiving end on emergency phone. Monitor and repair if/before worsens.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH 7.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. Operator added chemicals and adjusted to 7.2. Corrected.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing weekly total alkalinity and cyanuric acid. PH recorded at 7.0 with no correction or closure. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator updated records with weekly readings and correction of chemicals added. Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room. Dry chemicals on floor. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.