Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLINKS AT REA FARMS, THE - NORTH
Address7420 N REA PARK LN
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/4/2025
Final Score @ Grade
14
General Comments30 Day Intent to Suspend for test kit and records.Contact Marie Daley at 704-507-6806 when test kit is in and records will be verified. Updated CPO to Ezequiel Espinal No Night Swimming Motor was replaced and passed electrical inspection May 2024. “W” status

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing days of entries, not accurate. Test kit turned black, not accurate for reading. .2535(10) Provide test kit capable of measuring PH, disinfectant level, cyanuric acid and total alkalinity. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *30 Day Intent to Suspend (ITS)
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Leaves on pool floor covering some of main drains. .2537(14) Keep pool surface and pool floor free of debris. Operator cleaned and corrected.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No 1 weir missing. .2518(k) Replace missing weirs. Operator replaced missing weir. Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room. Dry chemicals on floor. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.