NameASCENT AT MALLARD CREEK APARTMENTS
Address2506 HOPE WAY LN
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/10/2024
Final Score @ Grade
10
General CommentsInspection conducted with CPO Galo Samaniego. New gates installed. Verified gates on battery backup. Observed new shower installed, flow meter working, new US Coast guard approved ring buoy and throw rope, most other items from previous inspection corrected. CPO tested cyanuric acid today. Got 100ppm, which is the state maximum. Recommend draining and adding fresh water and maintain at less than 100ppm. Permit issued No Night Swimming Paper permit will be posted on our website in 3-5 business days for your records.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No recent total alkalinity checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Corrected. CPO took sample today.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Post-2010 fence with some sections < 48" high due to buildup of pine straw. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Corrected. Gate at restrooms not self-closing and self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.