3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 6.8. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No records on the weekends. No recent, total alkalinity or Cyanuric Acid checks. PH 8.0 for the last 2 weeks with no corrective action taken. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Intent to suspend item. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Missing a few wall tiles. .2537(14) Maintain pool walls in good condition.
Pool floor dirty. Black algae growing on pool floor. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer baskets with debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Throw rope not securely attached to ring buoy. Throw rope 48 feet long. .2530(a) Provide USCG approved ring buoy with 50 foot throw rope at least 1/4 inch in diameter. - Immediate suspension item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not working. .2518(g) Keep flow meter operational. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pump room door standing open when I arrived. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator.
Fan off in the chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Shower not functioning. .2526(h) Shower(s) shall be provided. |