NameHOME 2 SUITES BY HILTON CHARLOTTE NORTHLAKE
Address7227 SMITH CORNERS BV
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/23/2026
Final Score @ Grade
28
General CommentsInspection conducted with CPO David Lopez Zanelli. Pool recently painted, existing main drain covers still in place. New motor installed on pump. Prior to 2026 pool permit being issued will need an electrical permit and passing inspection from Code Enforcement. Permit COM-ELC-25-004235 obtained, have not yet called for an inspection. Cyanuric acid tested at 0ppm. Intent to suspend issued 5) 8) 23) 24)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Filter pressure at 30psi, no record of when filter was last backwashed, no maintenance activities recorded. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmers not functioning. Operator able to get one to work by turning on the vacuum line. .2518(k) Replace missing weirs. - intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder loose. .2521 Install ladders per manufacturer instructions. Handrail loose. .2521 Install ladders per manufacturer instructions.
22 6 Premises: emergency telephone provided No No No Emergency phone not functioning. .2530(f) Emergency phone shall remain operable. - Corrected.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Salt cells off, part on order. Erosion feeder also off, not being used. Use only NSF approved chlorinator to chlorinate the pool. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. - Intent to suspend item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed flow meter not functioning. .2518(g) Keep flow meter operational. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Most chemicals stored in HVAC room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Some piping not labeled. Line labeled as vacuum controls the skimmer. .2518(d) Piping and valves shall be labeled with color codes or labels.