NameHOME 2 SUITES BY HILTON CHARLOTTE NORTHLAKE
Address7227 SMITH CORNERS BV
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 1/5/2023
Final Score @ Grade
32
General CommentsInspection conducted with Michelle Wallace. Observed both salt cells unplugged. Ensure salt cells and back up chlorinator are working properly. Observed large box of shock in the chemical storage room. Only use NSF approved chlorinator to chlorinate the pool. Note - Gate latches on gates for patio < 54” high. Patio is not part of the pool deck. Immediate suspension issued 2) 3) 15) Contact Will Harrison (704-507-6824) for re-inspection once issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No 0.1 ppm free chlorine. .2535(4) Maintain chlorine at least 1.0 ppm. - Immediate suspension item.
3 6 Water quality: pool water pH No No No PH < 6.8. .2535(1) Maintain pH at 7.2 to 7.8. - Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records not available during inspection. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. .2535(11) The pool operator must maintain records for at least six months. - Intent to suspend item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder loose. .2521 Install ladders per manufacturer instructions. Handrail loose. .2521 Install ladders per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Body hook not observed. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. Pole must be non-telescoping. - Immediate suspension item. Throw rope 19.5 ft long. .2530(a) Provide 22.5 ft throw rope for US Coast Guard approved ring buoy. - Immediate suspension item.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Light not operational at shallow end of pool. .2524(d) Provide sufficient underwater lighting.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Lock missing on heater enclosure. .2525(b) Heaters shall be equipped with thermostatic controls capable of assuring that the maximum operating temperature of heated public swimming pools other than spas does not exceed 90 degrees Fahrenheit. Such controls shall be accessible only to the operator. - Intent to suspend item.