General CommentsImmediate Suspension issued for pool pH. Once corrected, please contact Katie at 704-309-5494 to schedule a return visit to reopen the swimming pool. Vijay Chauhan present during the inspection. No signature due to covid restrictions.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
4 6 Water quality: water temperature of heated pool No No No Pool pH at 8.4. Lower to 7.2 to 7.8. Immediate Suspension issued.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Some reagents expired in test kit. Replace reagents. Noted CA at 60. Verified cyanuric acid at about 10 ppm at time of inspection. Ensure record keeping for cyanuric acid.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy rope tangled and could not be accessed. Untangled during inspection. Keep rope free of knots so that it is accessible at all times in case of an emergency.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Table and chairs <5 ft. to pool edge. Maintain 5 ft. clearance around the swimming pools in all locations.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Light not operational at shallow end of pool. Repair light.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Light burnt out in chemical storage room. Provide adequate lighting.