Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameOVERTON ROW
Address1201 CENTRAL AVE
 
City/State/ZIP
CHARLOTTE NC 28204
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/12/2025
Final Score @ Grade
22
General CommentsINTENT TO SUSPEND ISSUED FOR THE FENCE AND GATE LATCH VIOLATIONS. DEADLINE IS 12/12/2025. FAILURE TO RESOLVE THE ISSUES BEFORE THE DEADLINE MAY RESULT IN THE CLOSURE OF THE POOL. CONTACT C. ELMORE WHEN CORRECTIONS ARE MADE. 704-507-6814 OBSERVED THE DIRECTIONAL ARROWS ON THE PUMP ROOM PIPES TO HAVE WORN OFF OF MANY OF THEM. REAPPLY THE ARROWS TO SHOW THE DIRECTION OF FLOW THROUGH THE PIPES. MAIN DRAIN COVERS EXPIRE 3/20/2030. PERMIT RESTRICTION DOORS FROM FITNESS ROOM MUST REMAIN PERMANENTLY DISABLED.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed some gaps in the record log book. Ensure that the daily and weekly check are kept and properly recorded or every day the pool is open. No Permit Action taken. Ensure that cyanuric acid level is 100ppm or less in the pool.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed some greening on the main drain covers and on other surfaces inside the pool. Keep the pool clean.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed skimmer baskets to have a significant amount of debris in them. Keep the skimmer baskets clean to prevent the collection of debris in them. Observed interior wall of the skimmer between the sun shelf and the fence/gate section to be damage at the back of the skimmer interior in a way that could left water get under the deck and cause damage there.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Gate latches shall be 54" in height. Observed the gate latch to have dropped down where it is at 53 inches high from the deck. This must be corrected to where the handle stays up at 54 inches or higher. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Observed the fence next to the gate to be missing some screws that hold the vertical members in place. This means that the bars are not secured and at least one could be pushed out of place. Repair this and secure all of the fence bars.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed the flow meter to be stuck at the top of the scale. Correct the flow meter.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Observed some bags of pool chemicals on the floor of the pump room. Observed a bag of bicarbonate stored on a self under bottles of acid. Do not store such solid under such liquids as the liquids could spill or drip on them and Cause a hazardous reaction.