15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide at least 12 ft. long pole with body hook securely attached.
Observed body hook on 8 foot 7 inch pole that was collapsible.
.2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible.
Body hook was moved to a proper pole and attached. -C.D.I. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool deck furniture to be 5 inches too close to the pool water edge. Items were moved. -CDI. Keep items at least 6 feet away. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Emergency phone shall remain operable. Observed call box to connect, but be unable to carry voice communication without the microphone dropping out the sound of the person speaking. This made clear communication not possible. Pool is closed to swimming until box is corrected and correction is verified by the Health Department. Call box must function properly on call out and call back. Address and phone number must be posted at the box and also be on recorded with local 911 services. I.S. Issued. Contact C. Elmore at 704-507-6814 when correction was made. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed wet floor at filters. Correct this condition. |