NameOVERTON ROW
Address1201 CENTRAL AVE
 
City/State/ZIP
CHARLOTTE NC 28204
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/24/2021
Final Score @ Grade
26
General Comments15 - Ring buoy rope at 48 ft. Rope length corrected to 50 ft. during inspection. Ring buoy grab rope degrading. Replace with USCG approved ring buoy within 30 days. Will verify on return visit. 22 - Emergency phone not ringing back to pool deck when number dialed. Verified callback. Phone does not have ring sound and must know to push button to answer the phone. Change to audible ring or automatic pick-up. Given 30 days to correct. Intent to Suspend issued for window limiter and flow meter. Matt KHAMSANHIONA present during the inspection. No signature due to covid restrictions.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Pool pH at 8.4. Corrected to 7.4 during the inspection.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Missing logs for January. Feb and March provided. Ensure daily record keeping for chlorine, pH and main drain checks. Weekly record keeping for cyanuric acid and total alkalinity.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One window missing limiter. Replace window limiter at 4" or less. Intent to Suspend issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Pavers surrounding perimeter of pool. Noted growth of algae and some greenery in between pavers where polymeric sand is located. Polymeric sand is required on pavers to provide impervious surface. Will require reseal of polymeric sand prior to 2022 operating season.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No One pool light not operational. Pool hours are hours of front office. Repair light.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operable. Repair flow meter. Intent to Suspend issued.