| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records not maintained for cyanuric acid or total alkalinity. Pool had been closed to the public. Ensure weekly record keeping for cyanuric acid and total alkalinity. Intent to Suspend issued. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Plaster/pool surface worn away at bench around wall return. Repaired with pool putty during the inspection. Continue to monitor. May require repair prior to 2022 operating season. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Some skimmer baskets damaged. Replace as needed. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
No diving marker covered with deck finish. Added sticker during the inspection. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder rungs >6" from pool wall. Maintain 3" to 6" between ladder rung and wall. Original construction. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
One wall inlet missing eyeball fitting. Replace fitting. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Grill area provides foothold. Pool built prior to 2010. No corrective action. Eliminate footholds. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Deck/coping damage in multiple areas. No offsets >1/2" and no rough edges. Noted most severe damage near deck drain. Repair decking around deck drain at back side of pool prior to 2022 operating season. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Valve broken on chlorinator line to system. Replace/repair valve. Small leak. Intent to Suspend issued. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meters installed on 2" return lines installed per mfg. instructions but do NOT meet 1.5x design flow of the pump. For Whisperflo pump, flow meter on SCH40 pipe must go to at least 147 gpm. For flow meter installed on Challenger pump, flow meter on SCH40 pipe must go to at least 188 gpm. Intent to Suspend issued. Install flow meter approved for system per mfg. instructions. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pump room floor wet due to leak at chlorinator valve. Keep pump room floor dry. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
One stall missing toilet paper in women's restroom. Corrected during the inspection. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
No check valve on fill line to pool and hose bib connected to fill line on pump room. Install per .2512. Original construction. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
No hose bib in restrooms. Original construction. Provide hose bibs with backflow prevention. |