Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameKELTONWOOD AT BEREWICK APARTMENTS
Address5620 KELTONWOOD RD
 
City/State/ZIP
CHARLOTTE NC 28278
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/20/2023
Final Score @ Grade
32
General CommentsInspection conducted with operator, Natan. Immediate suspension of permit due to chlorine less than 1.0 ppm. Pool closed with signs posted during visit today. Pool must remain closed until corrected and verified by Mecklenburg County Public Health. Call Hope McIintosh at 980-229-7549 once corrected. Once permit is reinstated, the following items will be evaluated and if remain out of compliance a 30 day intent to suspend the permit may be issued. Chairs on pool edges, buildup around fence resulting in less tha 45” between horizontals. EHS will also re-evaluate operation of emergency phone during re-visit. Night swimming is not approved. Note: Filtration and feature pump main drains expire 8/2024. Replace all 4 drain covers and submit PDSC for approval prior to drain cover expiration.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm. Chlorine at 0.6ppm. Immediate suspension item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Skimmers with accumulated debris. Cleaned during inspection.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Rope attached to ring buoy greater than 52’ long. Operator corrected to 50’.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). Observed accumulated landscaping materials around base of fencing above bottom horizontal resulting in less than 45” between horizontals. *permit item
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed chairs removed from sun shelf and placed adjacent to pool edge. *permit item
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. Kings III operator unable to route calls to local 911 from this line. After mulitple attempts and service of line from Kings III, operator was able to route call to local 911 as required. EHS strongly recommends operator have the line evaluated to ensure it continues to operate as required.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some items within 3' of equipment in pump room. Appliances and other storage in pump room. Chemicals in storage room. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. Ventilation in chemical storage not operational.