2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Chlorine 0 ppm at time of inspection. .2535(4) Maintain chlorine at least 1.0 ppm.
**Immediate suspension item. Contact Marie Daley at 704-507-6806 to lift suspension
*NOTE: Chlorine must come up through chlorinator, shocking not permissible for corrective action |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 7.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. Immediate Suspension item. Contact Marie Daley at 704-506-7806 when in compliance to lift suspension. Pool MUST REMAIN CLOSED until suspension is lifted by Health Dept. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records missing weekly total alkalinity and cyanuric acid checks and are not accurate (7.4 pH for every day recorded).
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*Permit item, will check on return visit |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
Depth markers on pool wall not visible or accurate due to high water level. .2523(a) Provide depth markers on pool walls and pool deck at both ends of the pool.
*permit item |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Buoy rope around buoy broken and rope tangled. Keep accessible.
.2530(a) Provide USCG approved ring buoy.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. (Pool requires 50ā rope)
*Immediate suspension item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Some items within 3' of equipment in pump room. Dishwashers and other storage in pump room. Chemicals in storage room. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Men's restroom toilet soiled.