Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs. One missing weir observed from skimmer on far side of pool. Replace weir. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521(b) Ladders shall have slip-resistant tread. Missing tread from top step of pool ladder on near side of pool. Replace missing tread.
.2521 Install ladders per manufacturer instructions. Ladder rungs were missing from 2 pool ladders. Install ladder rungs. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Side access gate is missing a vertical rod which creates a 9” gap between verticals. Operator placed wire over this gap secured only with zip ties and a metal sign screwed into other verticals. Missing vertical rod needs to be replaced prior to permitting. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Loose tiles were noted on main pool deck and a small area at corner of pool deck where tree roots are pushing up pool deck tiles creating large 2 to 3 inch offsets. Repair deck. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep flow meter operational. Flow meter appeared to be stuck at 105 GPM. Permit restrictions require 169 gpm to 208 gpm. Repair or replace flow meter to ensure an accurate reading can be taken. |