8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs. Several missing weirs observed.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Excessive debris observed in several skimmer baskets. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521 Install ladders per manufacturer instructions. Two ladders were missing both ladder rungs. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Three outlets in pool wall were missing covers.
.2537 (b)(9) Underwater light niches shall be maintained or covered so as not to present a potential hazard to bathers. An underwater light was separated from pool wall socket. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Rope length provided with ring buoy was 37ft. Pool requires 45ft rope. Operator attached 45ft. Rope. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Provide no openings in fence and/or gate greater than 4"x4". Side access gat was missing a vertical bar creating an 8 inch opening. Operator corrected onsite by attaching sheet metal to cover opening. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep flow meter operational. Flow meter was inoperable. Operator cleaned sand out of flow meter during inspection to enable flow meter to properly operate. |