General CommentsPDSC form verified.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Two out of six weirs were missing. One was replaced. The other had a damaged fitting so the weir could not be replaced. No permit action taken as 5 out of 6 weirs are in place.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy was missing rope. They provided new rope and we cut to required 45’.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing unless an attendant AND lifeguard are present. One gate that was chained shut did not properly latch when chain was removed. This was damaged by a break-in and that is why they chain it shut. The old hardware was removed and the new hardware added allows door to self-close, self-latch is is greater than 54 inches in height.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Flow meter was not operating. It was removed and when reinstalled it began operating.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be kept dry and free of standing water. Observed some standing water in the pump room. Did not observe any leaks. All equipment is operational.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No .2518(d) Piping and valves shall be labeled with color codes or labels. Directional arrows were faded so operator relabeled during inspection.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(j) Provide soap and soap dispenser, no glass, at each sink. Soap missing in men’s restroom. .2526(m) Keep restrooms and fixtures clean and in good repair. One sink in women’s restroom is severely damaged and needs to be replaced.