Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameBRYANT APARTMENTS, THE
Address2020 MORTON ST
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 1/30/2024
Final Score @ Grade
20
General CommentsIntent to suspend issued. Contact Chris Sells when repairs are compete at 704 576. 8678. Permit will be suspended in 30 days if items are not corrected. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010).

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed no records since October 2023. Intent to suspend item. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Observed several skimmer baskets with debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed gap under fence greater than 7 inches to right of gate at parking lot. Intent to suspend item. .2528(a) Maintain 2" or less under fence and/or gate (post-May 2010).
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed several areas with greater than 1/2 inch offsets around deck drain. Intent to suspend item. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed no spare pump basket. .2518(e) Provide a spare basket for pump.