Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAVENUES AT STEELE CREEK
Address13001 YORKRIDGE DR
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/15/2025
Final Score @ Grade
12
General CommentsInspection conducted with GM Derrick Anthony and other CPO staff onsite. Previous listed CPO no longer with property. New CPO is Tim Pietrantonio, license number NC*0910249153, expiration date September 10th 2029. Ensure daily and weekly records are kept when open. Permit issued. Pool placed on A status and able to open. EHS Devon Moeller recommends resurfacing pool before 2026 season. Pump not labeled. Documentation provided for pump. Coping by skimmer repaired. Magnetic latch foothold on gates re installed to be closer to the gate to not provide a foothold. No listed permit conditions. Rope length 45’ Construction date 6/1/1990 No night swimming

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope 60ft. Operator cut to approved 45ft. Corrected. No permit action.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(e) Provide a spare basket for pump. Spare pump basket missing. Operator provided one by end of inspection. Corrected. No permit action.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room. Unable to identify any backflow prevention device on any hose bibs around pool. No 3' clearance around piping and equipment. Water on floor in pump room. Pool built '90. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump .2533(d) Pump room floor shall be kept dry and free of standing water.