NameAVENUES AT STEELE CREEK
Address13001 YORKRIDGE DR
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/7/2022
Final Score @ Grade
16
General Comments30 Day Intent to Suspend (ITS) for doors and inlet fittings. Contact Marie Daley at 704-507-6806 when corrected to lift ITS. Note: Automatic feeder not reading same as pool water. Advised calibrating to correct water quality. Updated CPO to Tyrone Attles

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gaps under fencing by grill area and on left greater than 4". Pool built '90. .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Door from clubhouse onto pool deck not self-closing at time of inspection. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. *Permit item
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Pool chairs within 6' of pool at time of inspection. .2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved chairs. Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Inlet fittings missing in pool. .2518(i) Arrange inlets to produce uniform circulation. *permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room. No backflow prevention device on any hose bibs around pool. No 3' clearance around piping and equipment. Ventilation not working. Water on ground in pump room. Pool built '90. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. .2533(d) Pump room floor shall be kept dry and free of standing water.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Labels fading on piping, main drain label gone. .2518(d) Piping and valves shall be labeled with color codes or labels.