General CommentsObserved bonding wire detached from pump. This was repaired during inspection by maintenance. Visit completed with Nelvin Johnson and Jeff Kirk present. Intent to suspend permit issued for door leading from fitness center to pool deck not self-latching or audibly alarmed and cracked skimmer basket. Correct within 30 days or permit may be suspended.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed the pH at 8.2. CDI- adjusted to 7.4.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing or damaged skimmer basket. Observed 1 skimmer basket cracked.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope connected to buoy greater than 35 feet. CDI- adjusted to 35 feet.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed door from fitness area to pool self-closing but not self-latching or audibly alarmed. Intent to suspend permit issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool furniture within 6 feet of pool. CDI- furniture relocated.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed no sign posted for emergency phone with address or phone number. CDI- sign posted.