Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed both main drain covers replaced with no PDSC documentation completed and submitted to the department for approval.
*Immediate suspension of permit |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Surface skimmers shall be installed per manufacturer's instructions. Weir in skimmer backwards - not operating properly. Operator corrected during inspection. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
.2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Damaged/missing face plate on pool overflow opening. Replace.
*Intent to suspend item |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Both windows in fitness center and both windows in office that open directly onto pool deck not limited to 4” opening. Windows must either be limited to opening less than 4” or prevented from opening.
*Intent to suspend item |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Emergency phone shall remain operable.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone.
Kings III phone not working - connects to operator but operator cannot hear to communicate. Phone number posted at the box is faded to the point that it is no longer legible.
*Immediate suspension item |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
.2513(b) Filter backwash shall be discharged through an air gap. Observed only an air break for backwash piping. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
.2526(l) Provide toilet paper and dispensers in restrooms. Observed no toilet paper and soap in restroom.
.2526(j) Provide soap and soap dispenser, no glass, at each sink.
No soap/towels in either restroom. No toilet paper in mens restroom. |