Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameEMERSON AT MONTFORD PARK
Address1520 MOCKINGBIRD LANE
 
City/State/ZIP
CHARLOTTE NC 28209
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/14/2022
Final Score @ Grade
8
General CommentsInspection completed with Stephen Hanson present. Intent to suspend issued for 2 sets of doors leading from lobby to pool deck not self-latching and 1 door at back of pool not self-latching. Correct within 30 days or permit may be suspended. In-field plan review completed during inspection. See below. 1.Permit Restriction Pump must remain at speeds 3110 to 3450 rpm to meet turnover requirement of 101 gpm. - Observed flow at 170 GPM after backwash. Observed filter set at 2600 RPM. CDI- adjusted to 3450 RPM. 2. Filtration Pump Pentair Intelliflo VSF 022056, 3 hp pump - verified and accurate. 3.Feature Pump Pentair Superflo 342001, 1.5 hp pump - verified and accurate. 4.Filtration Piping 4” md and sk; 3” return - verified and accurate. 5.Feature Piping 3” md and (3) 1.5” returns - verified and accurate. 6.(2) Aquastar 1216xxx with teal dots - verified and accurate. 7.(2) 914xxx with teal dots - verified and accurate. 8.(2) TR100C filters - verified and accurate. 9.15 returns 10 on floor and 5 on wall - verified and accurate. 10.5 skimmers - verified and accurate.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Observed doors leading from lobby area to pool deck not self-latching and 1 door at back of pool deck not self-latching. Intent to suspend issued. Correct within 30 days.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed pool furniture within 6 feet of pool. CDI- furniture was relocated.