15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Buoy rope tangled at time of inspection and short. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator untangled, retied at other end and corrected.
18 foot rope required, rope starting to deteriorate, but passable, advised new rope prior to next inspection |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals and other items stored in pump room, within 3’ of equipment and piping. Dry chemicals on floor in chemical storage. Vent broken in chemical room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
.2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. |