Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHOME 2 SUITES BY HILTON CHARLOTTE PIPER GLEN
Address5110 PIPER STATION DRIVE
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/7/2023
Final Score @ Grade
8
General CommentsMain drain covers expire July 2024. Replace and submit updated PDSC form to PDSC@mecknc.gov for approval PRIOR to expiration to avoid permit action. Discussed not using stabilized chlorine tablets in indoor pool, cyanuric acid is usually not needed.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Buoy rope tangled at time of inspection and short. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Operator untangled, retied at other end and corrected. 18 foot rope required, rope starting to deteriorate, but passable, advised new rope prior to next inspection
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals and other items stored in pump room, within 3’ of equipment and piping. Dry chemicals on floor in chemical storage. Vent broken in chemical room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.