16
|
1.50
|
Food-contact surfaces: cleaned & sanitized |
Yes |
Yes
|
No |
4-601.11 (A) Equipment, Food-Contact Surfaces, Nonfood Contact Surfaces, and Utensils (Pf) Food contact surfaces shall be clean to sight and touch. Observed a slicer stacked as clean with food debris on the blades and a pair on tongs stacked as clean with oily residue still on them. A food employee was informed and these items were placed to be rewashed. CDI. REPEAT VIOLATION. |
|
37
|
0
|
Food properly labeled: original container |
No |
Yes
|
No |
3-302.12 Food Storage Containers Identified with Common Name of Food (C) Working Containers of food must be label with their common name unless they are easily identifiable such as rice or pasta noodles. Observed sauce and oils bottles without labels.
You can also use a color coding system with rubber bands on oil bottles since labels won't stick to these containers well. |
|
47
|
0
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
Yes |
Yes
|
No |
4-202.11 Food-Contact Surfaces - Cleanability (Pf) A) Multiuse FOOD-CONTACT SURFACES shall be: (1) SMOOTH; and (2) Free of breaks, open seams, cracks, chips, inclusions, pits, and similar imperfections. Observed a severely chipped silicon spatula. A food employee was informed and discarded it upon request. CDI. |
|
49
|
0
|
Non-food contact surfaces clean |
No |
Yes
|
No |
4-601.11 (B) and (C) Equipment, Food-Contact Surfaces, Nonfood Contact Surfaces, and Utensils (C) (C) NonFOOD-CONTACT SURFACES of EQUIPMENT shall be kept free of an accumulation of dust, dirt, FOOD residue, and other debris. Observed minor debris inside of the microwave. |
|
54
|
0
|
Garbage & refuse properly disposed; facilities maintained |
No |
Yes
|
No |
5-501.114 Using Drain Plugs (C) Drains in receptacles and waste handling units for REFUSE, recyclables, and returnables shall have drain plugs in place. One of the outdoor dumpster is missing a drain plug.
Drain plugs are needed to prevent attracting and harboring pests. |
|
55
|
0
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
6-501.11 Repairing - Premises, Structures, Attachments, and Fixtures - Methods (C) PHYSICAL FACILITIES shall be maintained in good repair. Observed minor repair issues to ceiling in the food preparation area. Also observed gaps between tile and wall in the restroom.
EHS would only expect a fast correction on this if ownership changed, just slowly work on compliance in this regard. |